Seller guide

How to identify medium voltage cable before you sell it

Most medium voltage cable can be identified without unwinding a foot of it. The jacket legend, the reel tag and the cut end carry almost everything a buyer needs.

Start with the printed legend

Cable is printed every few feet along the jacket. A single readable section usually contains the manufacturer, the voltage rating, the conductor size, the insulation type, the shield description and any listing marks. Photograph two or three sections because print fades unevenly and one section is often scuffed.

Read the voltage class correctly

A legend showing 15 kV describes the insulation level, not the system voltage it was installed on. Common classes are 5 kV, 15 kV, 25 kV and 35 kV, with 2 kV and 8 kV appearing in older plant work. Record the number printed on the cable rather than the number on the drawings.

Identify the conductor and its size

Copper and aluminium look different at a cut end, and the legend usually states which. Size appears as AWG or kcmil, for example 4/0 AWG or 500 kcmil, sometimes with a conductor count for multi-conductor cable. If the end is sealed, photograph the seal instead of opening it.

Note the insulation and shield

Medium voltage cable is normally EPR or XLPE insulated with semi-conducting screens and a metallic shield, either tape or wire. The legend will say which. This detail matters because shield type and condition affect both reuse and handling.

Record the footage from the reel tag

Reel tags usually carry a starting and ending footage. Both numbers together give the remaining length. If the tag is missing, measure the wrap depth and the flange diameter and label the result clearly as an estimate.

Photograph the reel, not just the cable

Buyers need to see flange condition, banding, storage position and whether the reel can be lifted safely. One wide photograph of the reel and one close photograph of the legend is a better submission than ten photographs of the same jacket.

Do not cut or test to identify

Cutting a length to prove the conductor destroys footage and may expose insulation to moisture. Testing is work for qualified personnel on de-energised cable under the site's electrical safety programme. Identification does not require either.

Published 2026-11-08Texas Electrical Wire Buyers
02

Questions on this topic

Short answers to the details sellers ask about most.

What if the jacket print is completely gone?
Then the reel tag, the purchase records and the physical construction become the evidence. Measure the conductor, note the insulation and shield, and photograph the cut end. The lot can still be reviewed, but it will be valued with more caution.
Can I identify voltage class from the cable diameter?
Not reliably. Insulation thickness varies by construction and manufacturer. Diameter can support an estimate, but the printed legend or the tag should be the basis for any claim.
Is it safe to read a cable end?
Reading a de-energised, disconnected cable end is normally safe, but confirming that it is de-energised is a qualified electrical task. Never assume a cable is dead because it is disconnected at one end.
Next step

Send the lot for review

Include the voltage class, conductor size, footage and the Texas city where the reels are stored.

Medium voltage buying page

Request a wire quote

Voltage, size, footage and city.

No fee and no obligation. Nothing is bought, moved or scheduled until written lot terms are agreed.

Prefer to talk? 954-740-1983 · saleselectricalbuyers@gmail.com

One desk for the whole state

Documented lots are reviewed on construction, condition and footage.

Call to Sell Wire